The high-voltage switch integrated tester refers to Part 3 of the General Electric Power Industry Standard “General Technical Conditions for High Voltage Test Equipment†as a design basis, providing convenience for dynamic analysis of various types of circuit breakers and capable of accurately measuring various voltage levels. Low oil, oil, vacuum, sulfur hexafluoride and other high-voltage circuit breaker mechanical dynamic parameters.
High-voltage switch tester technical indicators:
Environmental group: It belongs to the group of instruments in GB6587.1-1986 "General Principles of Electronic Measuring Instruments Environmental Test".
Type: Portable Packaging: Aluminum Alloy Case Size & Weight::
Host: 440×300×150(mm)5(kg)
Attachment: 440×300×80(mm)3(kg)
Working power: AC220V±10% Frequency: 50Hz±5%
Ambient temperature: -10°C~40°C Relative humidity: ≤85%
Insulation resistance: ≤ 2MΩ
Dielectric strength: The power input line can withstand 1.5KV 1 minute withstand voltage test for the case.
Time Test Range: 1~499.9ms Resolution: 0.01ms Accuracy ≤ 0.1ms
Speed ​​Test Range: 15m/s Resolution: 0.01m/s Accuracy ± 1% Reading + 2 words Stroke Test Range: Unlimited Resolution: 0.01mm Accuracy ± 1% Reading + 2 characters DC Power Selection Range: 25- 265V/10A Resolution: 1V: Accuracy ≤±1%
Daily maintenance of high-voltage switch tester:
(1) Please keep it in use. (2) During transport, please avoid falling or hitting.
(3) If it is not used for a long period of time in a humid climate or humid season, please apply electricity once a month for about two hours each time. When the instrument is not normally used, it should be stored indoors at a temperature of -10 to 40oC, a relative humidity of no more than 80%, ventilation, and no corrosive gas.
When using outdoors, try to operate under shade as much as possible to avoid direct sunlight in the sun for a long period of time.
High-voltage switch tester technical indicators:
Environmental group: It belongs to the group of instruments in GB6587.1-1986 "General Principles of Electronic Measuring Instruments Environmental Test".
Type: Portable Packaging: Aluminum Alloy Case Size & Weight::
Host: 440×300×150(mm)5(kg)
Attachment: 440×300×80(mm)3(kg)
Working power: AC220V±10% Frequency: 50Hz±5%
Ambient temperature: -10°C~40°C Relative humidity: ≤85%
Insulation resistance: ≤ 2MΩ
Dielectric strength: The power input line can withstand 1.5KV 1 minute withstand voltage test for the case.
Time Test Range: 1~499.9ms Resolution: 0.01ms Accuracy ≤ 0.1ms
Speed ​​Test Range: 15m/s Resolution: 0.01m/s Accuracy ± 1% Reading + 2 words Stroke Test Range: Unlimited Resolution: 0.01mm Accuracy ± 1% Reading + 2 characters DC Power Selection Range: 25- 265V/10A Resolution: 1V: Accuracy ≤±1%
Daily maintenance of high-voltage switch tester:
(1) Please keep it in use. (2) During transport, please avoid falling or hitting.
(3) If it is not used for a long period of time in a humid climate or humid season, please apply electricity once a month for about two hours each time. When the instrument is not normally used, it should be stored indoors at a temperature of -10 to 40oC, a relative humidity of no more than 80%, ventilation, and no corrosive gas.
When using outdoors, try to operate under shade as much as possible to avoid direct sunlight in the sun for a long period of time.
Solar Flood Light,Led Flood Light,Outdoor Solar Light,Portable Rechargeable Floodlight
Jiamei Energy(hongkong) Limited , https://www.jiameilight.com