During the maintenance of the CMM, Edward Coordinate Measuring Co. feels that the following problems should be noticed, which is also our experience and lessons in the process of using CMM.
During the maintenance of the CMM, Edward Coordinate Measuring Co. feels that the following problems should be noticed, which is also our experience and lessons in the process of using CMM.
1. Air pressure and quality The coordinate measuring machine generally adopts air bearing, and the minimum air pressure for working should be 0.45 MPa. The air pressure should be kept between 0.5-0.8 MPa during the work to ensure the good work of the coordinate measuring machine. Although sometimes the air pressure can be operated in a 0.45 MPa machine, it should be considered that the air pressure will be lost during the operation of X, Y and Z, so that the gap of the air floating block is small. If there are dust or fine particles in the air floating block, it will cause The guide rail is scratched, which seriously affects the measurement accuracy or causes the three-axis operation to be stuck.
2. Wiping of the guide rail and maintenance of the grating The guide rail must be kept clean. Wipe it with a cotton wool or silk cloth soaked with clean aviation gasoline or absolute ethanol. Pay special attention when loading and unloading parts to prevent bumping the guide rail.
The maintenance of the scale directly affects the accuracy of the reading, the Z-axis scale is exposed to the external environment, and the X and Y-direction scales are covered by the cover. Therefore, pay special attention to the Z-axis scale to prevent scratches. Wipe with a clean aviation petrol silk cloth and dry it.
3. Cleaning of the filter The filter should be cleaned regularly. When the filter element of the filter is found to be discolored, it must be cleaned. Remove the plastic cup, strainer, wash with a neutral detergent (we use carbon tetrachloride solution), and then dry with a clean gas. After reinstalling, measure the working pressure and adjust it if necessary.
4. Maintenance of the electronic control system The electronic control system is the core part of the coordinate measuring machine. It should be said to be relatively stable, but it should not be neglected to check and maintain it. For long-term use, some interfaces and inserts may be loose. Once we found out that after the power-on, the axis "Home" error alarm, the investigation found that the original interface is caused by loose.
Original address: http://, please indicate the source.
Http://news.chinawj.com.cn Editor: (Hardware Business Network Information Center) http://news.chinawj.com.cn
We supply full range of abrasive tools, such as Flap Disc adhesive, Flap Disc Backing Pad, Abrasive Flap Disc, Flap Wheels , flap wheel with shaft, Abrasive Sanding Disc, Abrasive Machine , etc...
both one component epoxy adhesive and two component epoxy adhesive.
Specifications for single component epoxy adhesive for flap disc:
Appearance: Colloidal
Color: Blue / White
Odour: Slight odour
Proportion(water=1):1.42
Viscosity (25℃, mpa.s): 15000~20000
Storage time: 5℃ 6 months
Recommended curing condition: 110~130℃×4~3 hours or 150~160℃×1 hour
Hardness(Shore D): ≥90
Recommended temperture on the machine: 40-52 degree
Shearing strength(23℃, steel/steel, MPa): ≥22
Flap Wheel Glue Instructions
According to the ambient temperature, preheat adhesive among 41 ~ 46℃ before pumping into the pumping system.
Note:
1.When climate is colder, adjust preheating temperature 3 ~ 5℃ higher than normal.
2.Before use large quantities,a small quantity should be used for test.
3.This flap disc glue is a chemical product, can cause weak corrosive to skin, please note that the use of the appropriate protection, such as inadvertent contact with the skin with plenty of water rinse or alcohol wash.
4.Baking temperature is particularly important for product quality. The data provided by us is tested under accurate oven temperature control. We are strongly advised customer should adjust oven temperature according to the customer's on site condition.
Storage and transportation
Flap Disc Adhesive resin glue should keep in cool, ventilated warehouse, temperature does not exceed 40℃, relative humidity of not more than 85% ,this product is not special goods, according to the general cargo transport.