Cooling tower noise control technology and cooling tower noise reduction scheme, Shenzhen Quelte Sound and Noise Reduction Engineering Technology Co., Ltd. specializes in cooling tower noise control and cooling tower noise reduction . Cooling towers are usually installed on the roof, refrigeration equipment installed in the ground floor or basement, the noise of the building and the surroundings have had an impact, and because many more complex noise sources, noise control to bring a certain degree of difficulty. The management of such noise requires comprehensive consideration and comprehensive control of noise in a multi-system manner.
Noise control design requirements : The equivalent sound level radiated from the engine room to the outside world meets the noise limit of Category 6 in the “Code for Noise Control Design of Industrial Enterprises†GBJ87-1985, ie ≤60dB(A) at night; equivalent sound in the room The level meets the noise limit of Class 1 in the Acoustic Environmental Quality Standard GB3096-2008, that is, ≤55dB(A) between daytime and ≤45dB(A) at night.
Noise source analysis : Generally , the noise pollution problem has been considered in the design process. When designing and selecting equipment, some sound and noise elimination treatments have been considered. Such noise sources are mainly concentrated in chillers, chilled water circulation pumps, cooling water circulation pump cooling towers, and the like. Through the octave spectrum analysis of the above devices, the peak noise of these devices is mainly concentrated below 500HZ (inclusive), showing obvious low-frequency characteristics. Because the medium and low frequency noise has strong diffractive properties and long propagation distance, it will bring difficulty to the management.
Estimation of the main noise source Unit: dB ( A )
Serial number | Main sound source | Leq |
1 | High-efficiency variable frequency centrifugal chiller vibration | Have a noticeable vibration |
2 | Cooling water circulation pump | 85.0 |
3 | Chilled water circulation pump | 87.5 |
4 | Cooling Tower | 75.0 |
5 | High-efficiency variable frequency centrifugal chiller integrated noise | 86 |
Â
The noise control scheme is mainly designed from the following aspects:
First, the machine room is soundproof Â
Second , the chiller and cooling water circulating water pump shock absorption
Third, the pipeline system shock absorption
Fourth , the cooling tower cooling fan sound insulation and cooling tower water disinfection
Design of the cooling tower noise management scheme according to the actual needs and requirements for conditions such as: installation location, the type of the sound source, the noise level and frequency of environmental / environmental requirements, ventilation requirements, noise reduction goals, targeted to the art design.
Shenzhen Quelte Sound and Noise Reduction Engineering Technology Co., Ltd. is an engineering technology company specializing in cooling tower noise control and cooling tower noise reduction, integrating product development, design, acoustic solutions and construction, specializing in mechanical equipment noise and Comprehensive vibration management and research to solve mechanical equipment noise, provide noise pollution survey and analysis for different types of mechanical equipment and equipment room, provide system mechanical equipment noise solutions and construction services.
Main business:
Industry: noise control of mechanical equipment, noise reduction, noise reduction , noise reduction of medical equipment, noise reduction, noise reduction of workshops, sound insulation and noise reduction, noise reduction of fan room, noise reduction of air compressor room , equipment production line noise reduction and other production equipment noise and environmental noise control in the plant area, sound insulation, shock absorption, noise reduction and other comprehensive noise control projects. All kinds of sound insulation doors, sound insulation windows, sound insulation rooms, sound insulation covers, sound insulation screens and other sound insulation projects.
Civil use: Noise reduction in residential quarters and residential houses , noise control in pump house, noise control in air conditioning systems, noise control in generator rooms, noise control in power distribution rooms, noise control in transformer rooms, noise control between machinery and equipment , hotel, office and office space Acoustic noise reduction , acoustic design and construction of functional buildings such as conference centers, concert halls, stadiums, and theaters.
Hastelloy is a nickel-base alloy that was originally developed as a container material for molten fluoride salts, to which it has good resistance in the temperature range 1300 to 1600ºF (705 to 870ºC).
The alloy has good oxidation resistance in air, and may be used to 1800ºF (980ºC) or intermittently to 1900ºF (1040ºC)
Grade : Hastelloy C276 (UNS N10276), Hastelloy C22 (UNS N06022), Hastelloy B2 (UNS N10665), Hastelloy C-4 (UNS N06455)
Standard : ASTM A564 / ASME SA564
Size : 1/8″ NB TO 24″ NB
Dimensions : ANSI/ASME B16.5, B 16.47 Series A & B, EN-1092, BS4504, BS 10, B16.48, DIN, etc.
Types : Weld neck Flanges (WNRF), Slip-on Flanges (SORF), Blind Flanges (BLRF), Lap Joint Flanges (SOLJ), Socket-weld Flanges (SWRF), Screwed (Threaded) Flanges, Long weld neck Flanges (LWNRF), Spectacle Blind Flanges Spacer & Blind Flanges, Ring Type Joint Flanges (RTJ), Reducing Flanges, Raised Face (RF) Flanges, Orifice Flanges, Large Diameter Flanges, Custom Flanges, Drawing Flanges, Forged Flanges, Plate Flanges, Flat Face Flanges, ANSI Flanges, ASME Flanges, BS Flanges, DIN Flanges, API, EN Flanges etc.
Class / Pressure: 150#, 300#, 600#, 900#, 1500#, 2500#. PN6, PN10, PN16, PN25, PN40, PN64 etc.
Hastelloy Flanges Specification:
Hastelloy Flange,Hastelloy Plate Flanges,Hastelloy Slip-On Flanges,Hastelloy Duplex Flange
Zhejiang Max Stainless Steel Co.,Ltd , http://www.cnstainlesstube.com